Repair and Rehabilitation of Structure after Fire Damage: A Case Study of an Industrial Building
| Author(s) | : | Pallavi Vangari, Mahesh Chavan, Navnath Khadake |
| Institution | : | Assistant Professor, Civil Engineering Department, JSPM’s ICOER Wagholi, Pune 412207, Maharashtra, India |
| Published In | : | Vol. 7, Issue 8 — August 2020 |
| Page No. | : | 21-26 |
| Domain | : | Engineering |
| Type | : | Research Paper |
| ISSN (Online) | : | 2348-4470 |
| ISSN (Print) | : | 2348-6406 |
This paper presents a case study on a rehabilitation of a fire damaged industrial building. Detailed siteinvestigation and NDT test are conducted to decide the repair methodology. The fire incident took place in a mixer unitof a 50 year old manufacturing unit. The fire ignited at ground floor due to short circuit in electric panel. The mixerbuilding is (RCC framed) ground and two upper floor structure. Concrete core samples are taken and tested for residualstrength. Rehabilitation plan is designed on the basis of site investigation and results of test conducted.
Pallavi Vangari, Mahesh Chavan, Navnath Khadake, “Repair and Rehabilitation of Structure after Fire Damage: A Case Study of an Industrial Building”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 7, Issue 8, pp. 21-26, August 2020.