🕔 Call For Paper — Vol. 13 | Issue 5 | May 2026 | Deadline: 31-May-2026
Track Paper Submit Paper Home
📢 NOTICE
📢 Call for Papers — Volume 13, Issue 5 (May 2026) | Submission Deadline: May 31, 2026 | Rapid peer review: 2–3 days | Impact Factor: 7.37 (SJIF 2026)

Paper Details

📄 IJAERD-OJS-3344

Choice of best transmission line conductor and percentage line compensation required in order to achieve best power evacuation scheme for IPP’s

Author(s):Shri Harsha J, Dr. R Prakash
Institution:Assistant Professor, Department of EEE, SSIT, Tumkur
Published In:Vol. 4, Issue 8 — August 2017
Page No.:79-88
Domain:Engineering
Type:Research Paper
ISSN (Online):2348-4470
ISSN (Print):2348-6406
Abstract

Private participation in generating power is being encouraged in the country in order to meet high powerrequirement. As a result, many independent power producers (IPP) are establishing pit head thermal power stations. Manya times, the IPPs have to execute a contract with the state electricity board, under whose jurisdiction the location of thegenerating plant comes up lies, that a certain percentage of the installed capacity of the plant shall be supplied to the stategrid and the balance power can be supplied to others. In such cases, there is a requirement for precisely controlled powerflow over a transmission line between the IPP’s generating station and the state grid substation at which the contractedpower is to be delivered and provision for evacuating the balance power to nearby state grid substation. In a case where theinstalled capacity of the IPP is 500 MW, 300MW of power shall be supplied to the state grid whenever the generation is morethan 300MW and full generated power if the generation is less than 300 MW. To achieve this control of power flow isessential. Hence it is required to select best conductor is required in order to reduce transmission losses and selection ofpercentage of compensation required to achieve control over the power flow in an AC transmission line. In this paperperformance analysis is carried out in order to select best transmission line conductor amongst various conductors availableand also percentage line compensation required to reduce reactive power flow and to control voltage and current in an ACtransmission line

🗎 Download PDF 🏆 Get Certificate
🕮 How to Cite

Shri Harsha J, Dr. R Prakash, “Choice of best transmission line conductor and percentage line compensation required in order to achieve best power evacuation scheme for IPP’s”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 4, Issue 8, pp. 79-88, August 2017.

Related Papers

📄 Submit Your Paper

Open Access • Peer Reviewed • CrossRef DOI
UGC Approved • Monthly Publication

Submit Now →
📅 Submission Deadline
31 May 2026
Vol. 13 | Issue 5
May 2026