🕔 Call For Paper — Vol. 13 | Issue 10 | October-2026 | Deadline: 26-Oct-2026
Track Paper Submit Paper Home
📢 NOTICE
DOI will be assigned to every published paper at no additional charge. 📢 Call for Papers — Volume 13, Issue 10 (October 2026) | Submission Deadline: October 26, 2026 | Rapid peer review: 2–3 days | Impact Factor: 7.37 (SJIF 2026)

Paper Details

📄 IJAERD-OJS-2906

Automatic Load Frequency Control of Three Area Power System Using ANFIS Based Controller

Author(s):YUVARAJ.A, MOHAN DASS.C, MOHAN.P, MOHAN.B, SREE DEVI.S.L
Institution:Students, Department of Electrical and Electronics Engineering, PERI Institute of Technology
Published In:Vol. 5, Issue 3 — March 2018
Page No.:1282-1289
Domain:Engineering
Type:Research Paper
ISSN (Online):2348-4470
ISSN (Print):2348-6406
Abstract

Load frequency control (LFC) is critical for the task and outline of current electric power frameworks.Corresponding necessary (PI) and relative basic subsidiary (PID) controllers are utilized to control the differentparameters of multi zone control framework. Because of high pinnacle overshoot and settling time, ordinary PI and PIDcontrollers are not favoured for extensive power framework. The principle inspiration of this task is to control the yieldrecurrence reaction with least pinnacle overshoot and settling time. This task introduces an ANFIS based wise loadrecurrence control approach for three region control framework with three control territories. The value of the proposedcontrolling method is that it is speedier than the programmed traditional control systems and can deal with the nonlinearities all the while. Additionally the most extreme overshoot and the settling time of ANFIS based controller arelesser when contrasted with the ordinary controllers, subsequently decreasing the motions locally and of between region.This adequacy of the proposed controller in enhancing the dynamic reaction is appeared and approved in three regionbetween associated frameworks. Examination in exhibitions of PI, PID control system and ANFIS control approach isdone in MATLAB/SIMULINK programming. The outcomes approves that the ANFIS based smart controller is quickerthan the customary controller and have enhanced dynamic reaction.

🗎 Download PDF 🏆 Get Certificate
🕮 How to Cite

YUVARAJ.A, MOHAN DASS.C, MOHAN.P, MOHAN.B, SREE DEVI.S.L, “Automatic Load Frequency Control of Three Area Power System Using ANFIS Based Controller”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 5, Issue 3, pp. 1282-1289, March 2018.

Related Papers

📄 Submit Your Paper

Open Access • Peer Reviewed • CrossRef DOI
UGC Approved • Monthly Publication

Submit Now →
📅 Submission Deadline
26 Oct 2026
Vol. 13 | Issue 10
October-2026