🕔 Call For Paper — Vol. 13 | Issue 10 | October-2026 | Deadline: 26-Oct-2026
Track Paper Submit Paper Home
📢 NOTICE
DOI will be assigned to every published paper at no additional charge. 📢 Call for Papers — Volume 13, Issue 10 (October 2026) | Submission Deadline: October 26, 2026 | Rapid peer review: 2–3 days | Impact Factor: 7.37 (SJIF 2026)

Paper Details

📄 IJAERD-OJS-4328

SLIPPAGE OF STEEL IN ENGINEERED CEMENTITIOUS COMPOSITES AND NORMAL STRENGHT CONCRETE

Author(s):Faisal Farhad
Institution:Department of Civil Engineering, University of Engineering and Technology, Peshawar, Pakistan
Published In:Vol. 6, Issue 7 — July 2019
Page No.:90-96
Domain:Engineering
Type:Research Paper
ISSN (Online):2348-4470
ISSN (Print):2348-6406
Abstract

The possibility of composite action of reinforced concrete member is dependent on the existence of sufficientbond strength between concrete and steel reinforcing bars that in turn helps to effectively transfer shear stress betweenthe two. The relationship between bond strength and compressive strength of concrete is directly proportional, thereby,higher concrete strength means higher bond strength. Therefore required development length can be reduced.Experimental investigations were carried out to evaluate the impact of development length on bond stress and sliprelationships. For this purpose, casting and testing of 24 pull-out samples, comprising of equal number of high andnormal concrete strengths, were carried out. As a result of the experiments, it was empirically found that bond strengthincreased for both high and normal strength concrete when development length was increased from 5db to 10 db asshown in figure Figure 11, 12 and 13. However, in case of normal strength concrete increase in bond strength is morecompared to that in high strength concrete as it is clear from Figure 11 and Figure 13. The increase in bond strength isobserved even at 10db development length but the extent is less for 19 mm than 16 mm bars as shown in Figure 12 andFigure 13. This is in agreement with the earlier findings of Chen et al and Harajli et al. However incase of HSC the totalslippage at 10db is 50% greater than at 5db. This may be due to the fact that more no of concrete keys participate inresisting the slippage.

🗎 Download PDF 🏆 Get Certificate
🕮 How to Cite

Faisal Farhad, “SLIPPAGE OF STEEL IN ENGINEERED CEMENTITIOUS COMPOSITES AND NORMAL STRENGHT CONCRETE”, International Journal of Advance Engineering and Research Development (IJAERD), Vol. 6, Issue 7, pp. 90-96, July 2019.

Related Papers

📄 Submit Your Paper

Open Access • Peer Reviewed • CrossRef DOI
UGC Approved • Monthly Publication

Submit Now →
📅 Submission Deadline
26 Oct 2026
Vol. 13 | Issue 10
October-2026